Fault Phenomenon: Bauer BG30 rotary drilling rig cab interior is stuffy, AC vents not blowing cold air.
Troubleshooting Process:
– Checked refrigerant: refrigerant leak, low pressure.
– Checked compressor: compressor clutch not engaging.
– Checked condenser: condenser clogged with dust.
– Checked filter: AC filter clogged.
Root Cause: The AC condenser surface is completely clogged with dust and leaves, causing poor heat dissipation and system high-pressure protection shutdown.
Required Parts: Clean condenser and recharge refrigerant.