Fault Phenomenon: Geek+ AGV forklift in a specific area of the warehouse experiences wireless communication interruption, tasks cannot be assigned.

Troubleshooting Process:
– Checked AP signal: weak signal.
– Checked interference: interference from metal racks.
– Checked antenna: antenna loose.
– Checked IP: IP conflict.

Root Cause: Metal racks in the warehouse cause a wireless signal blind spot.

Required Parts: Add wireless APs or adjust antenna positions.