Fault Phenomenon: General hydraulic forklift when overloaded, the safety valve does not open, causing structural damage.
Troubleshooting Process:
– Checked set pressure: pressure set too high.
– Checked spool: spool seized.
– Checked spring: spring broken.
– Checked for contaminants: debris stuck.
Root Cause: The safety valve spool is seized or the set pressure is incorrect.
Required Parts: Safety valve assembly and resetting.