Repair Cases

Genie IWP-20S Vertical Mast Battery Cover Lock Broken

Fault Phenomenon: Genie IWP-20S vertical mast aerial work platform battery cover cannot be locked securely, vibrates while driving.

Troubleshooting Process:
– Checked latch: latch broken.
– Checked spring: spring damaged.
– Checked cover: cover deformed.
– Checked frame: frame deformed.

Root Cause: The battery cover latch mechanism is mechanically damaged.

Required Parts: Battery cover latch.

Share: