Fault Phenomenon: SANY SG165 grader instrument displays incorrect or no blade angle data.
Troubleshooting Process:
– Checked sensor: potentiometer worn open circuit.
– Checked harness: harness worn, short to ground.
– Checked connection: sensor linkage detached.
– Checked power supply: 24V supply missing.
Root Cause: The internal potentiometer of the blade angle displacement sensor is worn and open circuit, preventing signal transmission.
Required Parts: Blade angle displacement sensor assembly.