Repair Cases

XCMG XR168E 1. Slew Oil Leak 2. Lubrication System Sensor Alarm 3. Hydraulic Circuit Fault

Problem Description:

1. Slew oil leak. 2. Lubrication system sensor alarm. 3. Hydraulic circuit fault.

Troubleshooting Steps:
– Balance valve block oil seal damaged; replaced.
– Grease valve block disassembled and cleaned.

Root Cause:

No specific record.

Required Parts:

Replaced damaged balance valve block oil seal; cleaned grease valve block.

Share: