Repair Cases

XCMG XR240E 1. Rotary Head Mud Ingestion and Noise 2. Rotary Head Valve Frame Cracked

Problem Description:

1. Rotary head mud ingestion and abnormal sound. 2. Rotary head valve frame cracked.

Troubleshooting Steps:
– Slewing ring.
– Large and small bearings.
– Pinion gears.

Root Cause:

No specific record.

Required Parts:

Replaced rotary head valve block; modified and replaced water seals.

Share: