Repair Cases

XCMG XR240E Main Hoist Cannot Hoist Rope

Problem Description:

Main hoist cannot hoist rope.

Troubleshooting Steps:
– Checked main hoist motor relief valve.
– Relief valve spool stuck.

Root Cause:

To be further checked.

Required Parts:

Cleaned valve spool and reinstalled; debugged and unit returned to normal operation.

Share: